160 kVA – 250 kVA

Features

Low OPEX: Best in class fuel efficiency with O2E technology

Robust and Reliable Product:Lowest maintenance and trouble free product with Kirloskar Liquid Cooled Engines

Start Type:Controller Based Easy Push Start Type

Customer Service:Quick and affordable door step service coverage (420+ service touch points and 6000+ KOEL trained service professionals on field)

Warranty:2 years warranty & labour free onsite service under warranty period

KRM:Critical genset parameters can be views on laptop or mobile

 

Product Specifications

Prime Rating at rated rpm ( as per ISO8528)1

kVA

160

180

200

250

kW

128

144

160

200

Genset Model

 

KG1-160WS

KG1-180WS

KG1-200WS

KG1-1-250WS

Frequency

Hz

50

50

50

50

Power factor

lagging

0.8

0.8

0.8

0.8

Voltage

V

415 3Ø

415 3Ø

415 3Ø

415 3Ø

Governing class (As per ISO 8528 Part-V)

G3

G3

G3

G3

Noise level

dBA

< 75

< 75

< 75

< 75

Fuel Consumption*

At 100% Load

Ltrs/hr

36.6

41.3

45.9

56.9

At 75% Load

27.7

30.9

34.4

42.6

At 50% Load

19.1

22.7

25.5

22.9

Fuel tank capacity

Ltrs

300

460

460

460

Weight of genset with canopy (approx..)^

Dry

Kg

2730

3900

3900

4010

Wet

Kg

3010

4300

4340

4320

Overall dimensions of genset^

Length

mm

4000

4300

4340

4340

Width

mm

1500

1740

1740

1740

Height

mm

1915

1970

1970

1975

Electrical Battery starting voltage

Volts-DC

12

24

24

24

ENGINE

Engine Model

6K1080TA G2

GSL1500TA G2

GSL1500TA G2

GSL1500TA G3

Rated output (Prime Continuous rating as per ISO 8528-1)

KW

147

183

183

228

HP

200

248

248

310

No. of cylinder

Number

6

6

6

6

Cubic capacity

Ltrs

6.48

8.86

8.86

8.86

Bore x Stroke

mm

150 x 125

118 x 135

118 x 135

118 x 135

Rated Speed

RPM

1500

1500

1500

1500

Aspiration

NA/TC/TA

TA

TA

TA

TA

Lube Oil change period

Hrs

500

500

500

500

Lube Oil Sump Capacity

Ltrs

18

27

27

27

Coolant Capacity

Ltrs

28

32

29.2

31.8

ALTERNATOR

Insulation Class

Class H

Ingression Protection

IP23

Alternator Efficiency (at 100% load) 0.8 pf**

93

93

93.5

93.6

Alternator Efficiency (at   75% load) 0.8 pf**

93.3

93.6

93.8

93.9

Permissible Voltage Dip at Full Load 0.8 0.8 pf**

< 20%

< 20%

< 20%

< 19%

Time Permitted to build up rated voltage at Rated RPM

< 1 sec provided engine reach the rated speed

Short Circuit Ratio

0.518

0.53

0.545

0.45

Short Circuit Withstand Time

sec

3 times rated current for < 3sec

Overload Withstand Capacity

%

10% overload for one hour once in 12 hours & for 150% for 30 sec

For Intermediate ratings, Kindly contact nearest KOEL office

Related posts

Leave a Comment